Agilent Varian VHS-6 Water Cooled Diffusion Pump ISO200K, 9.5 in. OD, Ext. Cap, 120V 2200W, L6193311
Agilent Varian VHS-6 Water Cooled Vacuum Diffusion Pump, ISO 200K Inlet Flange, 9.5 inch OD, Maximum Pumping Speed 2400 l/s
Extended Cold Cap, 120 VAC 2200 Watt Heater, Agilent Varian Part Number L6193311.

The Agilent Varian VHS-6 has been designed to fill a special need in applications where high pumping speeds are required and space limitations demand a compact pump. The VHS-6 pump is a rugged, general-purpose unit with an operating range of 2 x 10-3 to <5 x 10-9 Torr. The Agilent Varian VHS-6 is ideal for applications requiring fast cycling because of its high pumping speed (maximum rated at 2400 l/s) air combined with high forepressure tolerance (0.65 Torr with no-load and 0.55 Torr when at full gas load). Backstreaming rate of the unit is 1x10-4 mg/cm2/ min, without the use of any cooled cold cap.

This Agilent Varian VHS-6 Diffusion Pump Includes:
  • ISO 200K Inlet Flange no holes use LF ISO claw clamps for mating
  • KF50 Outlet Foreline Flange
  • Extended Cold Cap
  • 2400 l/s Maximum Pumping Speed Air
  • 120 VAC @ 2200 Watt Heater
  • Designed To Be Used With Santovac 5 Diffusion Pump Oil
Diffusion pumps use a high-speed jet of vapor to direct gas molecules in the pump throat down into the bottom of the pump and out the outlet. The oil diffusion pump is operated with an oil that has low vapor pressure. Its purpose is to achieve higher vacuum (lower pressure) than possible by use of positive displacement pumps alone. The Agilent Varian VHS-6 can pump down to pressures of <5x10-9 Torr. Diffusion pumps cannot discharge directly into the atmosphere, so a mechanical forepump, roughing pump is typically used to maintain an outlet pressure around 1 mTorr.

These Agilent Varian Diffusion Pumps are very reliable, simple in design and operate with no noise or vibration. Diffusion pumps are still the most economical means for creating high-vacuum pressures. Diffusion pumps also tolerate operating conditions such as excess particles and reactive gases that would destroy other types of high-vacuum pumps. They can be ordered with a 1-phase 115, 208, 240 VAC heater harness and with standard or extended cold cap. We stock and sell Santovac 5 diffusion pump fluids for this pump. Please see below in our “Related” section for additional accessories that may benefit your vacuum applications and maintenance needs. We offer a large variety of vacuum greases, oils, vacuum fittings, hoses, vacuum gauges, sensors/transducers, parts and accessories sold separately on this website.

These Agilent Varian VHS-6 diffusion pumps have ISO 200K inlet flange, operate on 1-phase 120 VAC, extended cold cap and has Agilent Varian part number L6193311. The Agilent Varian VHS-6 diffusion pump user's instruction manuals can be downloaded in PDF format below. These are typical stock items that often ship same day as order is placed.


ITEM DESCRIPTION PART NO.
1   Standard Cold Cap Assembly 86488301
2   Extended Cold Cap Assembly F6455001
3   Sight Glass Repair Kit consisting of:
Sight GlassL8816001
Gasket, TeflonL9694001
O-ring, Viton, Parker No. 2-113ComI
O-ring, Viton, Parker No. 2-226ComI
L8908301
4   Jet Assembly F3365301
5   Splash Baffle  
6   Foreline Baffle Assembly L9172301
7   Thermal Switch Includes:
7a - Switch (set at 300°F – 147°C)642906025
7b - Lug648056680
7c - Wire656179100
7d - Box Insulator89867001
L8912301
8   Heaters (one heater required per pump)
120 V / 2200 watt Heater Element647306125
208 V / 2200 watt Heater Element647306175
240 V / 2200 watt Heater Element647306225
9   Heater wire, 10 AWG, 36 inches (3 per pump required) X3901-68002
10   Lugs, Replacement, nickel 648056680
11   Heater Clamp Assembly, Includes:
11a - Heater Cover Plate86088001
11b - Heater Insulator86087001
11c - Heater Clamp Plate86086301
86643301
12   Heater Insulating Blanket L8998001
13   Heater Cover L8997001
14   O-Ring Kit includes:
  • 3 inlet flange O-ring, Butley Parker No. 2-267
  • 3 foreline flange O-ring, Butley Parker No. 2-332
  • 10 fill and drain O-rings (old style), Viton Parker No. 2-112
  • 10 fill and drain O-rings (new style, Viton No. 2-113
  • 1 Sight glass O-ring, Parker No. 2-226
  • 1 PTFE gasket
  • K0377184
    15   Baffle Retaining Ring 699992156
    16   Screw, Rd hd machine, no. 6-32x3/16, stainless steel Screw
    17   Stud, no. 8-32 x 1/2, stainless steel Stud
    18   Screw, Socket hd cap, no. 8-32x1/4, stainless steel Screw
    19   Viton Centering ring for ISO inlet flange, 200K IC200SV
    20   Centering ring for ISO foreline flange, KF50 KC50SV
    21   3/8 Hose 1/8 Pipe Barbed (included with the pump)
    22   Ceramic Bushing (included with the pump) 699006025
      NEOVAC SY diffusion pump fluid, 1000 cc K6948301
      DC-704 diffusion pump fluid, 500 cc 695474005
      DC-705 diffusion pump fluid, 500 cc 695475005
      Santovac 5 diffusion pump fluid, 500 cc 695405005
      Installation and Operation Manual-download from www.agilent.com/chem/vacuum 699901021
    Product: Agilent Varian VHS-6 Water Cooled Diffusion Pump ISO200K, 9.5 in. OD, Ext. Cap, 120V 2200W, L6193311
    Condition:      New
    Warranty:     As-Stated*
    Part Number: P106798
    Sale Price: $8,705.63       Regular Price: $9,672.92